From 44eb4e1b4bb07c23ebfb7008a1f18088dd60e46b Mon Sep 17 00:00:00 2001 From: "Wolfgang (Wolle) Ewald" Date: Wed, 6 Jan 2021 15:46:15 +0100 Subject: Update Alert_Window_Mode_with_Latch.ino --- .../Alert_Window_Mode_with_Latch.ino | 29 +++++++++++----------- 1 file changed, 15 insertions(+), 14 deletions(-) diff --git a/examples/Alert_Window_Mode_with_Latch/Alert_Window_Mode_with_Latch.ino b/examples/Alert_Window_Mode_with_Latch/Alert_Window_Mode_with_Latch.ino index f90d6db..da30b2d 100644 --- a/examples/Alert_Window_Mode_with_Latch/Alert_Window_Mode_with_Latch.ino +++ b/examples/Alert_Window_Mode_with_Latch/Alert_Window_Mode_with_Latch.ino @@ -2,13 +2,14 @@ * Example sketch for the ADS1115_WE library * * This sketch shows how you can use the alert pin with the latch function. The -* only difference to Alert_Window_Mode.ino is that latch is enabled (line 112) -* and that the alert needs to be cleared (line 147). Try and see the difference. +* only difference to Alert_Window_Mode.ino is that latch is enabled (line 113) +* and that the alert needs to be cleared (line 148). Try and see the difference. * As an alternative to the unlatchAlertPin function you can use getResult_V. * Internally clearAlert just performs a read of the conversion register. * * Further information can be found on: -* https://wolles-elektronikkiste.de/ads1115 +* https://wolles-elektronikkiste.de/ads1115 (German) +* https://wolles-elektronikkiste.de/en/ads1115-a-d-converter-with-amplifier (English) * ***************************************************************************/ @@ -59,7 +60,7 @@ void setup() { */ adc.setCompareChannels(ADS1115_COMP_0_GND); //uncomment if you want to change the default - /* Set number of conversions out of limit after which the alert pin will be active + /* Set number of conversions out of limit after which the alert pin will assert * - or you can disable the alert (including conversion ready alert) * * ADS1115_ASSERT_AFTER_1 -> after 1 conversion @@ -90,10 +91,10 @@ void setup() { */ adc.setMeasureMode(ADS1115_CONTINUOUS); //comment or change if you want to change single shot - /* Choose maximum limit or maximum and minimum alert limit (window)in Volt - alert pin will - * be active when measured values are beyond the maximum limit or outside the window + /* Choose maximum limit or maximum and minimum alert limit (window) in volts - alert pin will + * assert when measured values are beyond the maximum limit or outside the window * Upper limit first: setAlertLimit_V(MODE, maximum, minimum) - * In max limit mode the minimum value is the limit where the alert pin will be deactivated + * In max limit mode the minimum value is the limit where the alert pin assertion will be cleared * again (if not latched!) * * ADS1115_MAX_LIMIT @@ -102,9 +103,9 @@ void setup() { */ adc.setAlertModeAndLimit_V(ADS1115_WINDOW, 3.0, 1.5); //uncomment if you want to change the default - /* Enable or disable latch. If latch is enabled the alarm pin will be active until the - * conversion register is read (getResult functions). If disabled the alarm pin will be - * deactivated with next value within limits. + /* Enable or disable latch. If latch is enabled the alert pin will be active until the + * conversion register is read (getResult functions). If disabled the alert pin assertion + * will be cleared with next value within limits. * * ADS1115_LATCH_DISABLED (default) * ADS1115_LATCH_ENABLED @@ -113,16 +114,16 @@ void setup() { /* Sets the alert pin polarity if active: * - * Enable or disable latch. If latch is enabled the alarm pin will be active until the - * conversion register is read (getResult functions). If disabled the alarm pin will be - * deactivated with next value within limits. + * Enable or disable latch. If latch is enabled the alert pin will assert until the + * conversion register is read (getResult functions). If disabled the alert pin assertion + * will be cleared with next value within limits. * * ADS1115_ACT_LOW -> active low (default) * ADS1115_ACT_HIGH -> active high */ //adc.setAlertPol(ADS1115_ACT_LOW); //uncomment if you want to change the default - /* With this function the alert pin will be active, when a conversion is ready. + /* With this function the alert pin will assert, when a conversion is ready. * In order to deactivate, use the setAlertLimit_V function */ //adc.setAlertPinToConversionReady(); //uncomment if you want to change the default -- cgit v1.2.3